4-Axis (Scara) Robots:HM-E2 Series
Model name
  • HM-4060*E2 / HM-4A60*E2
  • HMS-4070*E2 / HM-4A70*E2
  • HM-4085*E2 / HM-4A85*E2
  • HM-40A0*E2 / HM-4AA0*E2
Arm length
  • Approx.600mm / 700mm
  • Approx.850mm
Max. payload 10 - 20kg
Cycle time 0.29 - 0.31sec.
Robot
Basic Spec. Dimensions
Basic/Overhead-mount Spec. Dimensions
Dust & Mistproof Spec. Dimensions
Dust & Mistproof/Overhead Spec. Dimensions
RC5 Controller
Basic Spec. Dimensions

Dimensions:Dust & Mistproof/Overhead

HMS-4070*E2-W
Type A B C D F G H
HMS-4070*E2-W 700 350 350 228 284° 431 284
Z axis stroke S(mm) L1 L2 L3
200 -696 -496 119
300 -796 -496 219
400 (Note 2) -896 -496 319
  • Note 1: The workable space is limited so that the unit does not interfere with the cables.
  • Note 2: In case of the overhead-mount, the Z axis in the uppermost position may reach higher than the base mounting face. Be careful with the interference with surrounding facilities.
HMS-4A70*E2-W
Type A B C D F G H
HMS-4A70*E2-W 700 350 350 228 284° 431 284
Z axis stroke S(mm) L1 L2 L3
200 -696 -496 119
300 -796 -496 219
400 (Note 2) -896 -496 319
  • Note 1: The workable space is limited so that the unit does not interfere with the cables.
  • Note 2: In case of the overhead-mount, the Z axis in the uppermost position may reach higher than the base mounting face. Be careful with the interference with surrounding facilities.
HMS-4085*E2-W
Type A B C D F G H
HMS-4085*E2-W 850 350 500 311 284° 439 237
Z axis stroke S(mm) L1 L2 L3
200 -696 -496 119
300 -796 -496 219
400 (Note 2) -896 -496 319
  • Note 1: The workable space is limited so that the unit does not interfere with the cables.
  • Note 2: In case of the overhead-mount, the Z axis in the uppermost position may reach higher than the base mounting face. Be careful with the interference with surrounding facilities.
HMS-4A85*E2-W
Type A B C D F G H
HMS-4A85*E2-W 850 350 500 311 284° 439 237
Z axis stroke S(mm) L1 L2 L3
200 -696 -496 119
300 -796 -496 219
400 (Note 2) -896 -496 319
  • Note 1: The workable space is limited so that the unit does not interfere with the cables.
  • Note 2: In case of the overhead-mount, the Z axis in the uppermost position may reach higher than the base mounting face. Be careful with the interference with surrounding facilities.

矢印Page Top